The laboratory of quartz crystal components environment and periodicity was built to meet the requirements of AEC-Q200 vehicle scale test.The laboratory can carry out Crystal Element performance test, mechanical test, environmental test and Reliability test.

Test projectStandard of experimentEquipment photo
Operating temperature 85℃ (plug-in) "* 1"Operating temperature 125℃ (SMD products)
High temperature storageCrystal is placed at 85℃±2℃ for 1000 hours "*2" Crystal at 125℃±2℃ for 1000 hours "*2"
Cycle of temperatureThe crystal does 1000 cycles at the table temperature below
The crystal does 1000 cycles at the table temperature below
Steady moisture heatThe crystal is placed at 85 ° C ±2 ° C and 85% humidity for 1000 hours "*2"The crystal is placed at 85 ° C ±2 ° C and 85% humidity for 1000 hours "*2"
Life of serviceCrystal at 85 ° C ±2 ° C for 1000 hours "*2" (rated VDD applied)Crystal at 125 ° C ±2 ° C for 1000 hours "*2" (rated VDD applied)
AppearanceCheck device structure, marking and process quality.No electrical testing is requiredCheck device structure, marking and process quality.No electrical testing is required
SizeUser and supplier specifications.No electrical testing is requiredUser and supplier specifications.No electrical testing is required
Strength of terminal
(Plug-in class)
Tensile force: A 227g tensile force applied along the terminal axis for 10±5 seconds. Bending: The load should be limited to 2.5±0.5mm away from the Crystal Element body to start bending, the added mass load is 227g, bending times is 3.
ImpactImpact mode Half sine wave 100G duration 6ms direction X, Y, Z axis, 6 sides, a total of 18 impacts
VibrationVibration frequency 10 ~ 2000Hz     Spoke 1.5mm
Scanning time 20 min     Directions X, Y and Z(12 cycles in each of the three directions)
Resistance to welding heatReflow soldering: Peak temperature: 260±5℃, time: 10 seconds ±1 second.
Ability to weldWelding temperature 245℃±5 ℃ immersion time 5 seconds ±0.5 seconds, flux rosin resin methanol solvent (1:4)
Characteristic of electrical propertiesPerform parameter tests according to batch and sample number requirements, and summarize and list the minimum, maximum, mean and standard deviation of the device at room temperature and the lowest and highest operating temperatures.
Panel bending (SMD)Apply pressure to the center of the product until it bends to a minimum of 2mm and holds for 60±5 seconds.
Terminal strength (SMD)A force of 1.8Kg was applied laterally for 60±1 second.
*1 Beyond the maximum operating temperature, can be in accordance with customer requirements of the operating temperature;
*2 Interval measurements are required at 250 and 500 hours during the 1000-hour test;